SINGLE ACTING MINI POWER-PACKS


TECHNICAL DATA
Gear Pump 3.1 cc/rev
Max Pressure 210 bars
Set Pressure 180 bars
Electronic Motor 12V-24V / 1800W
Plastic Tank Size 4L – 7L – 9L
Mounting Horizontal
Command Solenoid Lowering Valve

DIM A
4 Litre Tank 245 mm
7 Litre Tank 400 mm
9 Litre Tank 527 mm

UNIT PERFORMANCE AT 12 VOLT

grafico-minicentral-english

minicentral-volt

GENERAL

– Each unit has been tested before shipment
– Waterproofed starting relay with a green function diode.
– Plastic injected reservoir (no corrosion problem, visible oil level)

STARTING PROCEDURE

– The battery’s amperage depends on its use. A standard battery is enough for usual applications. A 300 amps-hour battery is more adapted for a more intensive use.
– Fill the reservoir and the system with sufficient CLEAN oil to maintain the level above the filter. Use a clean funnel fitted with a fine mesh wire screen.
NOTE: Do note use a cloth strainer.
– When starting the motor for the first time, alternately start and stop motor / pump unit several times until the pump is primed and full flow begins.
– Ensure that all air is bled from the system, preferably at its highest point with the system under pressure.
– Air in the system will cause erratic and noisy operation.

UNDER NO CIRCUMSTANCES MUST THE UNIT BE RUN WITHOUT OIL

DOWNLOAD FILE – Single Acting Mini Power Packs

PDF-icon